We have tested products for public safety for 90 years and we are accredited by the standards council of canada. Ulc canulcs536 standard for inspection and testing of fire alarm systems fifth edition. Ulc ulcs52909 2009aug14 smoke detectors for fre alarm systemsthrd edton. Ulc can ulc s536 standard for inspection and testing of fire alarm systems fourth edition. Shutoff valves tested and result in trouble signal. The monitoringcentral station is ulc listed for fire alarm monitoring. The verifications we perform are done so without compromise to the applicable codes or standards. Control unit and transponders which forms are to be completed. National canadian fire alarm code and standards cfaa. Low pressure supervisory device inspected and tested. Fire code interim alert fire alarm smoke detector sensitivity testing ulc s53604 alberta fire code 2006 september 16, 2010 for more information, please call 18664216929 or visit. Canulcs561 standard for installation and services for fire receiving centres and systems second edition. And in the way of a reminder, i should state that were currently all using the 04 version.
Fire code fire alarm smoke detector sensitivity testing. Canulcs536 standard for inspection and testing of fire alarm systems appendix a. Earn continuing education units with ul knowledge solutions. Canulcs561 standard for installation and services for.
Canulcs536 inspection and testing of fire alarm systems canulcs537 verification of fire alarm systems and possibly proposed canulcs573 installation of ancillary devices proposed. Can ulc s536 04 pdf dear members of the ulc committee on fire alarm and life safety equipment and system ulcsf. While we dont actually charge a fee to download the forms found on this page. Jan, 2020 the 19 editions of the canulcs524, s537 and s536 are not to be used in ontario at this time.
Over time alarm components can corrode and become contaminated with dirt and various other contaminants. Refer to appendix d for examples of inspection and. Finally, we dropped some files into the folder on mac a, and within minutes they appeared on mac b. This standard applies to visual signaling devices intended for indoor andor outdoor installation. This standard presupposes that, where provided, the. Nov 16, 2018 can ulc s536 04 pdf dear members of the ulc committee on fire alarm and life safety equipment and system ulc sf. Every day thousands of users submit information to us about which programs they use to open specific types of files.
Can ulc s536 04 for mac adds a small icon along the computers top menu bar. The fire protection technicians network forms page. Online fire alarm course offered by ulc canulc s537 with a discount code for canasa members. Online fire alarm course offered by ulc canulc s53604 with a discount code for canasa members. Click here to download an faq explaining iacet and ceus in greater detail. Canadian fire alarm verification part one documentation. The fire alarm system has been tested in accordance with ulc can4s536. In all other canadian jurisdictions, the verification standard canulcs53704 is based on the 01 edition of the installation standard when, in actual fact, canulcs52406 is referenced in the building code. A can ulc s536 04 standard for inspection and testing of fire alarm systems test and inspection must be documented on a form called an appendix e report in the newest revision of this standard its called an appendix c report. Underwriters laboratories of canada ulc list your products or services on engineering360. Mircom a copy of this report will be given to the following, who is the owner or owners representative for this building. Can ulc s536 04 fire alarm annual inspection test form subject.
The canadian standard for inspection and testing of fire alarm systems and can ulc s537. Ulc canulcs536 standard for inspection and testing of. Normes ulc underwriters laboratories of canada elabore et publie des normes et des specifications concernant des produits qui ont quelque rapport avec. Fire safety and protection can be a complicated subject. Canulcs53604 inspection and testing of fire alarm systems.
Canulcs57614 standard for mass notification system. Standard for inspection and testing of fire alarm systems ulc standard canulcs536r2018. From there you can drag and drop it to your itunes library if you wish, or play it directly. Existing elevator modernizationfire alarm interface. Canulcs52406 standard for installation of fire alarm systems canulcs53604 standard for inspection and testing of fire alarm systems. Ulc is pleased to announce the publication of the fifth edition of canulc s536, standard for. Note in particular that revised editions of ulcs536 and ulcs537 will be published in 2020. The originally formatted test report which includes canulcs53604 appendix e weve been featuring for a number of years is still available for comparison. Annual inspection and testing of building life safety systems author.
Two stage pull stations tested and functions confirmed. This form must include without exception the following. The originally formatted test report which includes can ulc s536 04 appendix e weve been featuring for a number of years is still available for comparison. Verification takes place when new fire alarm systems are put in place and when additions or modifications are made to existing fire alarm systems. The verification procedures outlined in canulcs537. Genesis temporal horn installation sheet edwards signals. Jun 16, 2019 can ulc s536 04 fire alarm annual inspection test form. It really doesnt get any more basic than the acceptance criteria set out in two familiar canadian reference standards. Trutest enables fire alarm technicians to measure the sensitivity of installed smoke detectors quickly, accurately, easily, and professionally.
The canadian standard for verification of fire alarm systems these courses are intended for individuals looking to gain a better understanding of the inspection, testing and verification procedures of fire alarm. Standards bulletin 200801 can ulc s536 04, inspection and testing of fire alarm systems interpretation of clause 5. The inspection and testing procedures outlined in canulcs536 ensure the fire alarm system and the various system components are still working correctly to provide an early warning of fire or other emergency. Standards bulletin 2024 canulcs536, standard for inspection and testing of fire alarm systems. While we do not yet have a description of the ulc file format and what it is normally used for, we do know which programs are known to open these files. Ulc 536 inspection and testing of fire alarm systems canulc s536 standard by underwriters laboratories of canada, 20. The bigger the job, the more questions you may have. Things to remember when conducting a canulcs53604 fire alarm inspection. Canulcs57614 standard for mass notification system equipment and accessories. Sdi fire can provide you with alarm component testers to make sure your alarms dont degrade and make sure they are operating properly. Z32 04 electrical safety and essential electrical systems in health care facilities b4407 safety code for elevators and escalators. Mar 30, 2019 can ulc s536 04 fire alarm annual inspection test form. Canulcs52406 standard for installation of fire alarm systems.
Trutest 800 kit, detector sensitivity tester with 15 telescoping pole and smoke400. Building life safety systems testing canadian fire alarm. Can ulc s52406 standard for installation of fire alarm systems can ulc s536 04 standard for inspection and testing of fire alarm systems. The individual performing the annual inspection and test of a fire alarm system in canada must follow the provisions of the applicable standard in this case either canulcs53604 or canulcs536 depending on which version of the national fire code of canada your province or territory has adopted. Canulcs57614, standard for mass notification system. Sensitivity tested record results in the device test record. Oct 15, 2019 canulcs53604 fire alarm annual inspection test form. Trutest 801 detector sensitivity tester tt801 head. The entire fire alarm system has been inspected and tested in accordance with canulcs536, inspection and testing of fire alarm systems. Refer to appendix d for examples of inspection and test record forms. This series is all about the canadian fire alarm testing standard canulcs536. Building diagrams are on site that clearly indicate the type and location of all smoke control equipment fans, dampers, etc. The standard covers discrete electrical control units, communication units, transport products which manipulate the data packets, interfaces, and accessories for mass notification systems. Ulc canulcs536 standard for inspection and testing of fire alarm systems fourth edition.
This first edition national standard, canulcs57614, standard for mass notification system equipment and accessories, was published in september 2014. This form is intended to provide the owner or fire inspector with an overview of what fire protection systems exist in the building and which systems were. Inspect usa trutest 801 detector sensitivity tester tt801. S536 either as part of the fire alarm system or, where no fire alarm system exists. Ulc is pleased to announce the release of a two new elearning courses, can ulc s536 04. Stepbystep procedures detail the inspections and tests for. Can ulcs53604 standard for inspection and testing of fire. Inspection, verification and commissioning of fire alarm systems as per can ulc s536, s537. Module one begins with an overview of inspection and testing procedures for fire alarm systems found in the s536 standard, including discussion about the general components of a fire alarm system, the control unit functions that are tested under canulc s536, the control unit inspection process, and the detailed system test and inspection. This information is required by the standard and by the ontario fire code and must be on site in the building. Indicate type of test performed on a fully charged battery select one. This series is all about the canadian fire alarm testing standard can ulc s536.
Bogus fire alarm verification appendix c documentation new. Standards bulletin 2025 canulcs537, standard for verification of fire alarm systems. The question on the first page regarding fire alarm documentation e1. Canulcs53704 appendix c2 g documentation to include the name and number of the fire signal receiving centre canulcs561, and the latest edition of can ulcs537, has expanded this section to impart the importance on fire monitoring. Underwriters laboratories of canada ulc is an independent product safety testing, certification and inspection organization. The verification procedures outlined in can ulc s537 ensure the fire alarm system and the various system components were installed properly and are working correctly. A canulcs53604 standard for inspection and testing of fire alarm systems test and inspection must be documented on a form called an appendix e report in the newest revision of this standard its called an appendix c report. Enclosed for can ulc s can ulc s ulc is pleased to announce. Comments the fire alarm system has deficiencies noted on the pages attached. Abnormally frequent false tripping of drypipe valves. This standard prescribes requirements for the inspection and testing of fire alarm systems and specifies the devices and functions to be inspected, tested, and documented for the periodic inspection and test. This first edition national standard, can ulc s57614, standard for mass notification system equipment and accessories, was published in september 2014. This standard prescribes requirements for the inspection and testing of fire alarm systems and. Fire log book 291, fire protection equipment maintenance.
Enclosed for canulcs canulcs ulc is pleased to announce. Refer to appendix d for examples of inspection and test record. The entire fire alarm system has been inspected and tested in accordance with can ulc s536, inspection and testing of fire alarm systems. Canulcs53604, inspection and testing of fire alarm systems, and.
These sensors have a limited service life usually ten years and some require regular battery s36. This includes equipment used in the field at your building, as well as equipment used in our src to receive signals. Very often, you can opt to phase the replacement of the conventional field devices over a number of years all such systems are capable of maintaining the existing level of protection in cxn building for as long as you need and in many hybrid type systems, the existing wiring can be utilized. Fire alarm inspection documents ontario municipal fire. Canulc s52902 english printed edition smoke detectors for fire alarm systems standard published 06062005 by underwriters laboratories of canada pdf available formats immediate download. That means we should all be on the same page when it comes to the testing of a fire alarm system as well as providing the physical documentation required for that testing. In all other canadian jurisdictions, the verification standard can ulc s537 04 is based on the 01 edition of the installation standard when, in actual fact, can ulc s52406 is referenced in the building code. Canulcs536 standard for inspection and testing of fire. Online fire alarm course offered by ulc can ulc s536 04 with a discount code for canasa members. This nationally accepted log book has over 100 pages of forms to record all your fire protection equipment maintenance duties. Alarm systems have many components that can fail or lose effectiveness over time. Canulc s53604 and s537 elearning program ul canada. The 19 editions of the canulcs524, s537 and s536 are not to be used in ontario at this time. Meets or exceeds 85 dba in an anechoic chamber at 10 ft.
Can ulc s536 04 pdf ulc is pleased to announce the publication of the fifth edition of canulc s, standard for. Fire log book 291, fire protection equipment maintenance log book canadian edition safety media inc. Module one begins with an overview of inspection and testing procedures for fire alarm systems found in the s536 standard, including discussion about the general components of a fire alarm system, the control unit functions that are tested under can ulc s536, the control unit inspection process, and the detailed system test and inspection. Fire alarm system verification number of organizationscompanies parties required can ulc s537 04, verification of fire alarm systems the following is an interpretation by the ulc subcommittee on installation, inspection and.
Fire alarm system verification number of organizationscompanies parties required canulcs53704, verification of fire alarm systems the following is an interpretation by the ulc subcommittee on installation, inspection and. Jul 11, 2019 the verifications we perform are done so without compromise to the applicable codes or standards. Canulcs53604 fire alarm annual inspection test form subject. The standard for inspection and testing of fire alarm systems. Jun 21, 2019 can ulc s536 pdf canulcs periodic inspections and test daily and monthly. The fire protection technicians network special reports index page. Z3204 electrical safety and essential electrical systems in health care facilities b4407 safety code for elevators and escalators. What goes into a ulc s561 fire monitoring installation. Whats unique here is that the installation, verification, and annual inspection standards are properly aligned with each other.
Skip breadcrumb navigation home education can ulc s536 04. All sprinkler u,c regulating control valves passed full flow test. In ontario, the fire code still references the 04 edition of canulcs536, so we need to keep using it until the fire code changes its reference which i suspect well see soon. Canulcs53604 fire alarm annual inspection test form. This is a bogus canulcs53704 appendix c verification form largely based on a 1997 version of a canulcs536 annual inspection form. Canulcs53604 inspection and testing of fire alarm systems printed this standard provides requirements for the inspection and testing of fire alarm systems and specifies the devices and functions to be inspected, tested, and documented for the periodic inspection and test.
1423 606 1355 424 1158 100 1001 1071 1037 1118 745 694 317 1254 880 555 845 8 1238 1018 339 819 1411 185 231 1468 799 193 122 754 17 255 853 206 1383 1286 913 1093 87 566 85 375